Neonatal non-contact respiratory monitoring based on real-time infrared thermography.



Neonatal non-contact respiratory monitoring based on real-time infrared thermography.

Source
Philips Chair for Medical Information Technology, RWTH Aachen University, Pauwelsstr, 20, 52074 Aachen, Germany. abbas@hia.rwth-aachen.de

Abstract

BACKGROUND:
Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring of neonatal vital signals based on infrared thermography as a new biomedical engineering application. One signal of clinical interest is the spontaneous respiration rate of the neonate. It will be shown that the respiration rate of neonates can be monitored based on analysis of the anterior naris (nostrils) temperature profile associated with the inspiration and expiration phases successively.

OBJECTIVE:
The aim of this study is to develop and investigate a new non-contact respiration monitoring modality for neonatal intensive care unit (NICU) using infrared thermography imaging. This development includes subsequent image processing (region of interest (ROI) detection) and optimization. Moreover, it includes further optimization of this non-contact respiration monitoring to be considered as physiological measurement inside NICU wards.

RESULTS:
Continuous wavelet transformation based on Debauches wavelet function was applied to detect the breathing signal within an image stream. Respiration was successfully monitored based on a 0.3°C to 0.5°C temperature difference between the inspiration and expiration phases.

CONCLUSIONS:
Although this method has been applied to adults before, this is the first time it was used in a newborn infant population inside the neonatal intensive care unit (NICU). The promising results suggest to include this technology into advanced NICU monitors.

Wednesday, March 25, 2015

Viscerocutaneous reflexes with abdominal wall pain: A study conducted in 1981 on pregnant women from a general practice



Viscerocutaneous reflexes with abdominal wall pain: A study conducted in 1981 on pregnant women from a general practice
Phe van der Veen
Thermology International 04/2013; 23(2):56-63.
ABSTRACT BACKGROUND: This is an article regarding an unpublished study that was designed and conducted in 1981, but publication in time was not possible due to the workload in the busy practice of the author. Temperature changes on the abdominal wall could be caused by nociceptive sensations in the viscera which are transfered to the surface via viscerocutaneous reflex pathways. Two aspects play a role in this: 1. An internal organ’s proximity to the skin, 2. That organ’s registration of function to the skin. This study addresses the registration of function of an organ on a specific site of the skin. The aim of the study was to investigate if infrared thermography can measure temperature changes associated with the functional status of a pregnancy. The null hypothesis was: during the course of pregnancy, there is no difference in skin temperature between the skin areas selected.

METHODOLOGY: The occurrence of viscerocutaneous reflexes was investigated by means of infrared thermography in a group of pregnant women who were cared for in a general medical practice.This observational study started on the first visit for a pregnancy check-up and at every check-up visit, the temperature was measured. Because the check-ups were scheduled by the doctor based on indications or on woman’s request, the number of measurement differs among women. We used a linear mixed-effects model to model the difference in temperature between the genital zone and navel zone, with week and complaint group as fixed effects.

INTERVENTION: On four areas of the abdominal wall, infrared thermography temperature measurements were taken on the abdominal skin.

RESULTS: During pregnancy, a significant temperature difference developed between the genital zone and the navel zone (t=-6.019), caused by lower temperature in the genital zone that became visible approximately in the 34th week of the pregnancy.

CONCLUSIONS: The null hypothesis should be rejected. Infrared thermography seems to be able to measure the viscero- cutaneous consequences of a visceral process on a physiological level. The investigation with pregnant women reported in this publication is relevant for two reasons, because the evidence based data show that: 1. Infrared thermography can play a role in the detection of processes in the viscerum. 2. Chronic pain of the abdominal wall cannot be an isolated entity. This confirms extensively documented literature published previously. Abdominal wall pain continues to be a major problem medically, economically, and socially. Abdominal problems must be ruled out explicitly when searching for the location of abdominal wall pain. Differential diagnostics are a prerequisite for determining a specific solution.

Wednesday, March 11, 2015

Infrared thermography in newborns: the first hour after birth.

Christidis I, Zotter H, Rosegger H, Engele H, Kurz R, Kerbl R. Department of Pediatrics, University of Graz, Austria.

OBJECTIVE: It was the aim of this study to investigate the surface temperature in newborns within the first hour after delivery. Furthermore, the influence of different environmental conditions with regard to surface temperature was documented.

METHODS: Body surface temperature was recorded under several environmental conditions by use of infrared thermography. 42 newborns, all delivered at term and with weight appropriate for date, were investigated under controlled conditions.

RESULTS: The surface temperature immediately after birth shows a uniform picture of the whole body; however, it is significantly lower than the core temperature. Soon after birth, peripheral sites become cooler whereas a constant temperature is maintained at the trunk. Bathing in warm water again leads to a more even temperature profile. Radiant heaters and skin-to-skin contact with the mother are both effective methods to prevent heat loss in neonates.

CONCLUSIONS: Infrared thermography is a simple and reliable tool for the measurement of skin temperature profiles in neonates. Without the need of direct skin contact, it may be helpful for optimizing environmental conditions at delivery suites and neonatal intensivecare units."

Ref. S. Karger AG, Basel