Thursday, December 3, 2015

Facial thermography is a sensitive and specific method for assessing food challenge outcome.

Facial thermography is a sensitive and specific method for assessing food challenge outcome.
Clark AT, Mangat JS, Tay SS, King Y, Monk CJ, White PA, Ewan PW.
Department of Allergy, Cambridge University Hospitals NHS Trust, Addenbrookes Hospital, Cambridge, UK.

BACKGROUND: Oral challenge is widely used for diagnosing food allergy but variable interpretation of subjective symptoms may cause error. Facial thermography was evaluated as a novel, objective and sensitive indicator of challenge outcome.

METHODS: A total of 24 children with a history of egg allergy underwent oral challenge, which were scored positive when objective symptoms occurred or negative after all doses were consumed without reaction. Facial temperatures were recorded at baseline and 10-min intervals. The difference between mean and baseline temperature (DeltaT), maximum DeltaT during challenge (DeltaT(max)) and area under curve of DeltaT against time (DeltaTAUC) were calculated for predefined nasal, oral and forehead areas, and related to objective challenge outcome.

RESULTS: There were 13 positive and 11 negative challenges. Median nasal DeltaTAUC and DeltaT(max) were greater in positive compared with negative challenges (231- and 5-fold, respectively; P < 0.05). In positive challenges, nasal temperatures showed an early transient rise at 20 min, preceding objective symptoms at median 67 min. There was a sustained temperature increase from 60 min, which was reduced by antihistamines. A cut-off for nasal DeltaT(max) of 0.8 degrees C occurring within 20 min of the start of the challenge predicted outcome with 91% sensitivity (positive predictive value [PPV] 100%) and 100% specificity (negative predictive value [NPV] 93%). Subjective symptoms occurred in four of 13 positive and three of 11 negative challenges.

CONCLUSIONS: Facial thermography consistently detects a significant early rise in nasal temperature during positive compared with negative food challenges, which is evident before objective symptoms occur. Thermography may therefore provide a sensitive method to determine outcome of food challenges and investigate the pathophysiology of food allergic reactions.

Thursday, November 5, 2015

Peripheral facial paralysis aided by infrared thermography.

Journal of Traditional Chinese Medicine, 1991 Jun, 11(2):139-45
Peripheral facial paralysis aided by infrared thermography.

We have carried out clinical observations on 34 patients with peripheral facial paralysis treated by
acupuncture therapy prescribed according to selection of treatment regimen on the basis of facial
thermogram and temperature. A comparison was made with a control group of 97 patients who received conventional acupuncture therapy only. It was found that: (1) The cure rate in the group of selecting acupoints by thermogram (hereinafter referred to as the thermography--aided treatment group) was 67.65%, with a marked improvement rate of 26.40%; while the cure rate of the conventional acupuncture treatment group (hereinafter called the conventional treatment group) was 46.39%, the marked improvement rate being 29.90%, indicating a significant difference in therapeutic efficacy between the two groups (P less than 0.02). (2) The average duration of acupuncture therapy for the thermography aided treatment group was 6.02 weeks, whereas that for the conventional treatment group, 24 weeks. There was also a significant difference between the two groups (p less than 0.01). (3) During the entire therapeutic course, 25.2 sessions of treatment were given on the average in the thermography--aided treatment group, and 78.8 sessions in the conventional treatment group, showing a very significant difference (P less than 0.001). The present thermography--aided method exhibits advantages over the conventional one in enhancing the cure rate and shortening the duration of treatment, which is worthy to be popularized in clinical practice. It is also of certain significance in standardization and scientification of acupuncture therapy.
Zhang D; Wei Z; Wen B; Gao H; Peng Y; Wang F.

Tuesday, November 3, 2015

Infrared thermography: a rapid, portable, and accurate technique to detect experimental pneumothorax.

Infrared thermography: a rapid, portable, and accurate technique to detect experimental pneumothorax.
Rich PB, Dulabon GR, Douillet CD, Listwa TM, Robinson WP, Zarzaur BL, Pearlstein R, Katz LM.

Source
Department of Surgery, School of Medicine, Medical Wing D Room 186, CB #7228, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-7228 USA. prich@med.unc.edu

Abstract
 
RATIONALE AND OBJECTIVE:
Pneumothorax (Ptx) is a life-threatening complication that can result from trauma, mechanical ventilation, and invasive procedures. Infrared thermography (IRT), a compact and portable technology, has become highly sensitive. We hypothesized that IRT could detect Ptx by identifying associated changes in skin temperature.

MATERIALS AND METHODS:
Bilateral nonpenetrating chest incisions or needle punctures were performed in 21 anesthetized rats. Rats were then randomized to no, bilateral, left, or right Ptx by either open (n = 16) or closed percutaneous (n = 5) puncture through selected pleurae. Real-time thermographic images and surface temperature data were acquired with a noncooled infrared camera.

RESULTS:
In all cases, blinded observers correctly identified each Ptx with real-time grayscale image analysis. When compared to either the ipsilateral baseline or an abdominal reference, experimental Ptx produced a significantly greater decrease in surface temperature when compared to non-Ptx control.

CONCLUSIONS:
These results demonstrate that portable infrared imaging can rapidly and accurately detect changes in thoracic surface temperature associated with experimental pneumothorax.

Thursday, October 29, 2015

Infrared thermography: a rapid, portable, and accurate technique to detect experimental pneumothorax.

Infrared thermography: a rapid, portable, and accurate technique to detect experimental pneumothorax.
Rich PB, Dulabon GR, Douillet CD, Listwa TM, Robinson WP, Zarzaur BL, Pearlstein R, Katz LM.

Source
Department of Surgery, School of Medicine, Medical Wing D Room 186, CB #7228, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-7228 USA.
prich@med.unc.edu

Abstract
RATIONALE AND OBJECTIVE:
Pneumothorax (Ptx) is a life-threatening complication that can result from trauma, mechanical ventilation, and invasive procedures. Infrared thermography (IRT), a compact and portable technology, has become highly sensitive. We hypothesized that IRT could detect Ptx by identifying associated changes in skin temperature.

MATERIALS AND METHODS:
Bilateral nonpenetrating chest incisions or needle punctures were performed in 21 anesthetized rats. Rats were then randomized to no, bilateral, left, or right Ptx by either open (n = 16) or closed percutaneous (n = 5) puncture through selected pleurae. Real-time thermographic images and surface temperature data were acquired with a noncooled infrared camera.

RESULTS:
In all cases, blinded observers correctly identified each Ptx with real-time grayscale image analysis. When compared to either the ipsilateral baseline or an abdominal reference, experimental Ptx produced a significantly greater decrease in surface temperature when compared to non-Ptx control.

CONCLUSIONS:
These results demonstrate that portable infrared imaging can rapidly and accurately detect changes in thoracic surface temperature associated with experimental pneumothorax.

Thursday, October 22, 2015

Skin temperature measured by infrared thermography after ultrasound-guided blockade of the sciatic nerve

Skin temperature measured by infrared thermography after ultrasound-guided blockade of the sciatic nerve.

van Haren FG, Kadic L, Driessen JJ.

Source
Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands.

Abstract
BACKGROUND:
In the present study, we assessed the relationship between subgluteal sciatic nerve blocking and skin temperature by infrared thermography in the lower extremity. We hypothesized that blocking the sciatic nerve will lead to an increase in temperature, and that this will correlate with existing sensory block tests.
METHODS:
We studied 18 healthy individuals undergoing orthopaedic surgery of the foot under ultrasound-guided subgluteal blockade of the sciatic nerve with 30 ml ropivacaine 7.5 mg/ml. Skin temperature was measured on the toes, the dorsal and plantar side of the foot, the malleoli, and the lateral side of the lower leg, just before sciatic nerve blockade and at 10-min intervals thereafter.
RESULTS:
Baseline skin temperatures showed a significant distal-to-proximal gradient. After sciatic block, temperatures on the blocked side increased significantly in the toes and foot. When comparing pinprick to skin temperature in a receiver operating curve, there was an AUC of 85.9% (95% confidence interval = 83.7-88.2%, P < 0.001). The medial malleolus (not being innervated by the sciatic nerve) showed no significant difference to the lateral.
CONCLUSIONS:
After sciatic nerve block, temperatures of the foot increased significantly. There was a good correlation between pinprick testing and infrared temperature measurement. This makes infrared skin temperature measuring a good test in determining block success when sensory testing is impossible.

© 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Wednesday, August 19, 2015

ADVANTAGES OF SPECTRON IR




ADVANTAGES OF SPECTRON IR


  • Manufacturer of Spectron IR 640x480 infrared camera with superior Vanadium Oxide detector for increased camera sensitivity
  • Authorized FLIR dealer. Providing the same camera line as many competitors
  • Broadest range of medical infrared cameras available
  • Offering 320x240 and 640x480 resolution cameras
  • Broadest and safest FDA indications for use for any telethermographic system available with specific indications
  • Active FDA registration since 2003
  • Spectron IR 640x480 cameras offer best spatial resolution for accurate temperature differentiation of region comparison
  • Spectron IR 640x480 cameras feature electronic focus – superior to autofocus
  • Four system configurations to choose from providing flexibility to fit a variety of clinical settings (Entry, Basic, Workstation, & Wall mounted)
  • Entry and Basic systems make for easy portable imaging application
  • Entry and Basic systems set up quickly for imaging
  • Workstation and Wall mounted systems designed for clinical and hospital use
  • Workstation and Wall mounted systems feature remote controlled camera height adjustment for quicker image acquisition and less patient stress
  • Workstation and Wall mounted systems provide ergonomics for clinician and provide high patient and referring doctor perception
  • U.S. Patented Medical Imaging Workstation
  • Spectron IR 640x480 cameras have the largest lens in the industry at 50 mm standard allowing more data to be captured
  • Purchase options include cash, check, wire transfer, and financing
  • Every system receives full professional analytical software a user can grow with
  • Multiple format viewing, data storage and data transfer
  • Single keystroke commands for ease-of-use and efficiency
  • Simple software layout for easy navigation
  • Pre-loaded and customizable imaging sequences
  • Free 1-year technical support with every purchase
  • Free equipment training provided with any system purchased which can be revisited anytime within the first year at no charge
  • Spectron IR cameras use heavy machined aluminum camera body for superior thermal stability
  • Spectron IR 640x480 cameras feature a narrow temperature range specifically designed for human imaging achieving the best accuracy
  • Open interpretation system allows interpreter choices for the user
  • Switch interpreters at anytime, at no charge, for any reason
  • Spectron IR only uses board certified interpreters (MD’s, DC’s, and DO’s)
  • Un-biased interpretation. All interpreters are independent from Spectron IR
  • File transfer for interpretation is encrypted complying with HIPPA regulations
  • Included marketing materials and patient templates
  • Superior customer service with screen share capabilities
  • Real people when you call

Wednesday, July 29, 2015

Can rotational atherectomy cause thermal tissue damage? A study of the potential heating and thermal tissue effects of a rotational atherectomy device

Cardiovasc Intervent Radiol 1998 Nov-Dec;21(6):481-6

Can rotational atherectomy cause thermal tissue damage? A study of the potential heating and thermal tissue effects of a rotational atherectomy device.

Gehani AA, Rees MR; Cardiac Research Unit, Killingbeck Hospital, Leeds, United Kingdom.

PURPOSE: Thermal tissue damage (TTD) is customarily associated with some lasers. The thermal potential of rotational atherectomy (RA) devices is unknown. We investigated the temperature profile and potential TTD as well as the value of fluid flushing of an RA device.

METHODS: We used a high-resolution infrared imaging system that can detect changes as small as 0.1 degree C to measure the temperature changes at the tip of a fast RA device with and without fluid flushing. To assess TTD, segments of porcine aorta were subjected to the rotating tip under controlled conditions, stained by a special histochemical stain (picrisirius red) and examined under normal and polarized light microscopy.

RESULTS: There was significant heating of the rotating cam. The mean "peak" temperature rise was 52.8 +/- 16.9 degrees C. This was related to rotational speed; thus the "peak" temperature rise was 88.3 +/- 12.6 degrees C at 80,000 rpm and 17.3 +/- 3.8 degrees C at 20,000 rpm (p < 0.001, t-test). Fluid flushing at 18 ml/min reduced, but did not abolish, heating of the device (11.8 +/- 2.9 degrees C). A crater was observed in all segments exposed to the rotating tip. The following features were most notable: (i) A zone of "thermal" tissue damage extended radially from the crater reaching adventitia in some sections, especially at high speeds. This zone showed markedly reduced or absent birefringence. (ii) Fluid flushing of the catheter reduced the above changes but increased the incidence and extent of dissections in the media, especially when combined with high atherectomy speeds. (iii) These changes were observed in five of six specimens exposed to RA without flushing, but in only one of six with flushing (p < 0.05). (iv) None of the above changes was seen in control segments.

CONCLUSION: RA is capable of generating significant heat and potential TTD. Fluid flushing reduced heating and TTD. These findings warrant further studies in vivo, and may influence the design of atherectomy devices.

Wednesday, July 22, 2015

Intraoperative thermographic monitoring during neurogenic thoracic outlet decompressive surgery

Vasc Endovascular Surg. 2003 Jul-Aug;37(4):253-7.

Intraoperative thermographic monitoring during neurogenic thoracic outlet decompressive surgery. 

Ellis W, Cheng S. Source Division of Vascular Surgery, University of Hong Kong Medical Center, Queen Mary Hospital, Hong Kong, China.

Abstract
This article reports the use of thermography to monitor 123 plexus decompressions for neurogenic thoracic outlet syndrome. The diagnosis and management of this disease continues to be controversial. Questions about pathologic mechanisms, the extent and frequency of muscular entrapment, scar, and interdigitations, as well as their relative contributions, remain. Thermographic visualization of the operated extremity allowed us to map and correlate thermal changes with specific surgical manipulations, as well as to analyze the tissues resected to better answer these questions. Initial thermal abnormalities indicating, usually, ulnar entrapments or irritation, normalized sequentially as discrete entrapments were resected. Thermographic monitoring continues to provide surgically useful information in one third of operations.

Wednesday, July 8, 2015

THERMOGRAPHY AS AN ADJUNCT WITH OTHER IMAGING MODALITIES TO EVALUATE THE PERFUSION OF FREEZING COLD INJURIES



THERMOGRAPHY AS AN ADJUNCT WITH OTHER IMAGING MODALITIES TO EVALUATE THE PERFUSION OF FREEZING COLD INJURIES

J.B. Mercer1, 2, J.E. Løkebø3 and L. de Weerd3
1Cardiovascular Research Group, Department of Medical Biology,
Faculty of Health Sciences, University of Tromsø, Tromsø, Norway.
2 Department of Radiology and
3Department of Plastic Surgery and Hand Surgery, University Hospital
of North Norway, Tromsø, Norway.

There is little international consensus on the management of freezing cold injuries (FCI) and treatment procedures vary from being aggressive (rapid amputation) to conservative (wait and see). The different approaches to treating such injuries can partly be explained by the complexity surrounding the injury. For example, with frostbite tissue freezing occurs which may involve only superficial tissues or may extend to the bone. The onset and severity of frostbite may be affected by a multitude of factors such as air temperature, wind speed, duration of exposure, amount of exposed area, and predisposing conditions such as poor or inadequate insulation from the cold or wind, immersion, altitude, impaired circulation from tight clothing or shoes, fatigue, injuries, circulatory disease, poor nutrition, dehydration, hypothermia, alcohol or drug use, and use of tobacco products. Damage to the frostbitten tissues is caused by crystallization of water within the tissues, typically between the cells, and by resulting changes in electrolyte concentration within the cells. Damage occurs during the freezing process. Further damage occurs during reperfusion of frostbitten tissue.Whatever the situation one of the key factors in recovery is adequate tissue blood perfusion. So whether one is interested in mapping the extent of such an injury in the acute phase or monitoring the effect of a treatment regime or assessing the final outcome, some form of blood perfusion measurement is desirable. An example of a multimodal imaging approach using CT angiography, MR, scintigraphy and thermography for investigating blood perfusion in a severe case of frost bite of the feet will be presented. It will be shown that thermography as a non-invasive method without the use of ionizing radiationwas helpful in confirming the diagnosis, assessing the severity of the injury, and finally monitoring the outcome of FCI.

Wednesday, June 17, 2015

Am J Surg. 2008 Oct;196(4):523-6. Links

Effectiveness of a noninvasive digital infrared thermal imaging system in the detection of breast cancer.

Arora N, Martins D, Ruggerio D, Tousimis E, Swistel AJ, Osborne MP, Simmons
RM. Department of Surgery, New York Presbyterian Hospital-Cornell, New York, NY, USA.

BACKGROUND: Medical infrared thermal imaging (MITI) has resurfaced in this era of
modernized computer technology. Its role in the detection of breast cancer is evaluated.

METHODS: In this prospective clinical trial, 92 patients for whom a breast biopsy was
recommended based on prior mammogram or ultrasound underwent MITI. Three scores
were generated: an overall risk score in the screening mode, a clinical score based on
patient information, and a third assessment by artificial neural network.

RESULTS: Sixty of 94 biopsies were malignant and 34 were benign. MITI identified 58 of 60
malignancies, with 97% sensitivity, 44% specificity, and 82% negative predictive value
depending on the mode used. Compared to an overall risk score of 0, a score of 3 or greater was significantly more likely to be associated with malignancy (30% vs 90%, P <.03).

CONCLUSION: MITI is a valuable adjunct to mammography and ultrasound,
especially in women with dense breast parenchyma.

Wednesday, June 10, 2015

Evaluation of digital infra-red thermal imaging as an adjunctive screening method for breast carcinoma: A pilot study

Int J Surg. 2014 Dec;12(12):1439-43. doi: 10.1016/j.ijsu.2014.10.010. Epub 2014 Nov 7.

Evaluation of digital infra-red thermal imaging as an adjunctive screening method for breast carcinoma: A pilot study. 

Rassiwala M1, Mathur P2, Mathur R3, Farid K3, Shukla S3, Gupta PK4, Jain B4. Author information

Abstract BACKGROUND: Early screening plays a pivotal role in management of breast cancer. Given the socio-economic situation in India, there is a strong felt need for a screening tool which reaches the masses rather than waiting for the masses to reach tertiary centers to be screened. Medical infra-red thermal imaging (MITI) or breast thermography as a screening test offers this possibility and needs to be carefully assessed in Indian scenario.

METHODS: The study involved 1008 female patients of age 20-60 years that had not been diagnosed of cancer of breast earlier. All the subjects in this population were screened for both the breasts using MITI. Based on the measured temperature gradients (ΔT) in thermograms, the subjects were classified in one of the three groups, normal (ΔT ≤ 2.5), abnormal (ΔT > 2.5, <3) and potentially having breast cancer (ΔT ≥ 3). All those having (ΔT > 2.5) underwent triple assessment that consisted of clinical examination, radiological and histopathological examination. Those with normal thermograms were subjected to only clinical examination.

RESULTS: Forty nine female breasts had thermograms with temperature gradients exceeding 2.5 and were subjected to triple assessment. Forty one of these which had ΔT ≥ 3 were proven to be having cancer of breast and were offered suitable treatment. Eight thermograms had temperature gradients exceeding 2.5 but less than 3. Most of these were lactating mothers or had fibrocystic breast diseases. As a screening modality, MITI showed sensitivity of 97.6%, specificity of 99.17%, positive predictive value 83.67% and negative predictive value 99.89%.

CONCLUSION: Based on the results of this study involving 1008 subjects for screening of breast cancer, thermography turns out to be a very useful tool for screening. Because it is non-contact, pain-free, radiation free and comparatively portable it can be used in as a proactive technique for detection of breast carcinoma.

Wednesday, June 3, 2015

Neonatal non-contact respiratory monitoring based on real-time infrared thermography.



Neonatal non-contact respiratory monitoring based on real-time infrared thermography.

Source
Philips Chair for Medical Information Technology, RWTH Aachen University, Pauwelsstr, 20, 52074 Aachen, Germany. abbas@hia.rwth-aachen.de

Abstract

BACKGROUND:
Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring of neonatal vital signals based on infrared thermography as a new biomedical engineering application. One signal of clinical interest is the spontaneous respiration rate of the neonate. It will be shown that the respiration rate of neonates can be monitored based on analysis of the anterior naris (nostrils) temperature profile associated with the inspiration and expiration phases successively.

OBJECTIVE:
The aim of this study is to develop and investigate a new non-contact respiration monitoring modality for neonatal intensive care unit (NICU) using infrared thermography imaging. This development includes subsequent image processing (region of interest (ROI) detection) and optimization. Moreover, it includes further optimization of this non-contact respiration monitoring to be considered as physiological measurement inside NICU wards.

RESULTS:
Continuous wavelet transformation based on Debauches wavelet function was applied to detect the breathing signal within an image stream. Respiration was successfully monitored based on a 0.3°C to 0.5°C temperature difference between the inspiration and expiration phases.

CONCLUSIONS:
Although this method has been applied to adults before, this is the first time it was used in a newborn infant population inside the neonatal intensive care unit (NICU). The promising results suggest to include this technology into advanced NICU monitors.