Wednesday, August 19, 2015

ADVANTAGES OF SPECTRON IR




ADVANTAGES OF SPECTRON IR


  • Manufacturer of Spectron IR 640x480 infrared camera with superior Vanadium Oxide detector for increased camera sensitivity
  • Authorized FLIR dealer. Providing the same camera line as many competitors
  • Broadest range of medical infrared cameras available
  • Offering 320x240 and 640x480 resolution cameras
  • Broadest and safest FDA indications for use for any telethermographic system available with specific indications
  • Active FDA registration since 2003
  • Spectron IR 640x480 cameras offer best spatial resolution for accurate temperature differentiation of region comparison
  • Spectron IR 640x480 cameras feature electronic focus – superior to autofocus
  • Four system configurations to choose from providing flexibility to fit a variety of clinical settings (Entry, Basic, Workstation, & Wall mounted)
  • Entry and Basic systems make for easy portable imaging application
  • Entry and Basic systems set up quickly for imaging
  • Workstation and Wall mounted systems designed for clinical and hospital use
  • Workstation and Wall mounted systems feature remote controlled camera height adjustment for quicker image acquisition and less patient stress
  • Workstation and Wall mounted systems provide ergonomics for clinician and provide high patient and referring doctor perception
  • U.S. Patented Medical Imaging Workstation
  • Spectron IR 640x480 cameras have the largest lens in the industry at 50 mm standard allowing more data to be captured
  • Purchase options include cash, check, wire transfer, and financing
  • Every system receives full professional analytical software a user can grow with
  • Multiple format viewing, data storage and data transfer
  • Single keystroke commands for ease-of-use and efficiency
  • Simple software layout for easy navigation
  • Pre-loaded and customizable imaging sequences
  • Free 1-year technical support with every purchase
  • Free equipment training provided with any system purchased which can be revisited anytime within the first year at no charge
  • Spectron IR cameras use heavy machined aluminum camera body for superior thermal stability
  • Spectron IR 640x480 cameras feature a narrow temperature range specifically designed for human imaging achieving the best accuracy
  • Open interpretation system allows interpreter choices for the user
  • Switch interpreters at anytime, at no charge, for any reason
  • Spectron IR only uses board certified interpreters (MD’s, DC’s, and DO’s)
  • Un-biased interpretation. All interpreters are independent from Spectron IR
  • File transfer for interpretation is encrypted complying with HIPPA regulations
  • Included marketing materials and patient templates
  • Superior customer service with screen share capabilities
  • Real people when you call

Wednesday, May 6, 2015

Clinical Application Of Thermography In Dentistry



Clinical Application Of Thermography In Dentistry

Thermography measurement in the clinical set up can be done on a given spot or over an extended area of interest. Infrared telethermography of the face in normal subjects have shown that men have higher temperatures than females. The rationale behind this is that men have more basal metabolic than women and his skin dissipates more heat per unit area of body surface. Similarly age and ethnicity variations in facial temperature can also occur. [14-16]

In Chronic Orofacial pain patients
Gratt and his colleagues in 1996 developed a classification system using telethermographs for patients with chronic pain. [17] They classified them as normal when selected anatomic area (∆T) values range from 0.0 to +0.250C, hot when it is >0.350C, and cold when it is <0.350C. When a selected anatomic area value is 0.26- 0.350C, the finding is classified as equivocal. Moreover they also found that hot thermographs had the clinical diagnosis of (1) sympathetically maintained pain, (2) peripheral nerve mediated pain, (3) TMJ arthropathy, or (4) maxillary sinusitis. Subjects classified with cold subareas on their thermographs were found to have the clinical diagnosis of (1) peripheral nerve-mediated pain (2) sympathetically independent pain. Subjects classified with normal telethermographs included patients with the clinicaldiagnosis of (1) cracked tooth syndrome (2) trigeminal neuralgia (3) pretrigeminal neuralgia (4) psychogenic facial pain. This system of thermal classification resulted in 92% agreement in classifying pain patients making it as an important diagnostic parameter. [12,17]

In TMJ disorders
Normal TMJ examination using thermography had showed symmetrical thermal patterns with a mean
∆T values of 0.10C. [12, 14, 18] On the other hand, patients affected with internal derangement and TMJ osteoarthritis showed ∆T values of +0.40C. [19, 20] Beth and Gratt in 1996 conducted a double-blinded clinical study to compare the ∆T values among active orthodontic patients, TMD patients and symptomatic TMJ controls. The results showed that the average TMJ area ∆T values as +0.20C, +0.40C, and +0.10C in these groups respectively.(21) The above findings suggest that tele-thermography can distinguish between patients undergoing active orthodontic treatment and patients with TMD. [12,21]

In quantification of thermal insult to pulp
Dental pulpal tissue is exposed to variety of thermal insult during various dental treatment modalities.
Of late for debonding of orthodontic brackets Eelectro Thermal Ddebonding (ETD) method is widely used, this technique although has many advantages than the conventional mechanical method can pose serious thermal damage to pulp. Cummings and his colleagues in 1999 performed an in-vitro study on extracted human premolar teeth applying ETD. Thermal imaging analysis was done using mercury cadmium terullide detector showed that the pulpal temperature increased from 16.80C- 45.60C, which can pose serious threat to pulpal vitality. It can be stated from the study that, ETD methods needs intermittent cooling of the teeth with simultaneous thermal imaging to prevent pulpal damage. [22] Similarly the use of ultra high speed air-driven instrumentation during cavity preparation can result in serious thermal insult to the pulp. To overcome this, it is believed that various coolants (air water spray or air/water alone) can be used to reduce the intrapulpal temperature and prevent subsequent damage to the pulp. It was only until 1979, when Carson and his colleagues performed a study employing thermography to determine the pattern of heat distribution and dissipation during ultra-speed cavity preparation using both an air-water spray and air only coolants to determine if a point heat source is generated. This study stated that the mean magnitude of temperature increases with both types of coolant, 2.80C and 3.670C, probably does not exceed the physiologic limits of the pulp. [23] 

In assessing inferior alveolar nerve deficit
Over the years numerous studies have shown that thermal imaging technique can play a vital role in effective assessment of inferior alveolar nerve deficit. [12,24] Gratt and his colleagues in 1994 stated that patients with inferior alveolar nerve deficit when examined showed ∆T values of +0.50C on the affected side whereas subjects with no inferior alveolar nerve deficit showed a symmetrical thermal ∆T value of +0.10C. [25] The authors stated that the changes are due to blockage of the vascular neuronal vasoconstriction and this was confirmed by the same colleagues in the same year when similar thermological picture was obtained in normal subjects by temporary blockage of the inferior alveolar nerve using 2% lidocaine. [26]

Qualitative evaluation of N2O concentration
N2O is a highly insoluble gas which is rapidly absorbed and is eliminated swiftly by the lungs, thus it is used widely either alone or in combination with other anesthetic agents. [27] Results of various studies have shown that leakage of N2O into the workplace can lead to adverse health effects such as reproductive, hematologic and nervous dysfunctions. [28] Studies on acute and chronic occupational exposures have shown that N2O air concentration levels as low as 50 parts per million (ppm) can result in bone marrow depression, paresthesias, altered concentration, impaired visual effects, alterations in vitamin B12 and plasma homocysteine concentrations. [29-31]

In response to these findings and in order to effectively control exposures several guidelines have been published that define appropriate use and control criteria for N2O usage. The ADA made 10 recommendations that address the use of appropriate engineering controls for proper scavenging. [32] However, they are proved futile and health hazards secondary to N2O exposure is still on the rise. Rademaker et al in 2009 conducted a study using infrared thermography to determine the effectiveness of two N2O scavenging systems- The Safe Sedate Dental Mask (Airgas, Radnor, Pa.) system (System I) and Porter Nitrous Oxide Sedation System (Porter Instrument, Hatfield, Pa.) (System II). The results suggested that neither of the system was able to control occupational exposure of N2O oxide below the NIOSH REL. [33]

Additional applications of telethermography
- Evaluation of cranio mandibular disorders. [34]
- Detection of carotid occlusal disease. [35]
- Quantification of the effects of post-surgical inflammation. [36]
- Quantification of the effects of analgesics, anti-inflammatory drugs, etc.
- In the diagnosis of myofacial symptoms.

Conclusion
Thermography aids in the assessment and staging of various dysfunctions of the head and neck region.The unique significance of thermography is both qualitative and quantitative assessment which helps in estimation of progression of the disease in a systematic manner. With the innovation of novel equipments and the state of the art facility, thermography in the near future will certainly re-emerge as a unique research tool in dentistry.

References
[1] Anbar M. Diagnostic thermal imaging: A historical technological perspective. In: Anbar M (ed). Quantitative Dynamic Telethermography in Medical Diagnosis. CRC Press: BocaRaton. 1994), pp 1-9.
[2] Adams F. Hippocratic Writings, In: Hutchins RM (ed). (Hippocrates, Galen, Vol. 10 of Great Books of the Western World, Univ. of Chicago, Encyclopedia Britannica Inc. 1952),pp 66-77.
[3] Wolf A. A History of Science and Technology and Philosophy in the 16th & 17th Centuries. 2nd ed., McKee D (ed). George Allen & Unwin: London. 1950, pp 66-77.
[4] Bedford RE. Thermometry. In: The New Encyclopedia Britannica, 15th ed, Chicago. Ill. 1992; 11: 702-703.
[5] Hardy JD. The radiation of heat from the human body: I-IV. J Clin Invest. 1934; 13: 593-620.
[6] Hardy JD, Muschenheim C. The radiation of heat from the human body: V. J Clin Invest. 1936; 15: 1-8.
[7] Weinstein SA. Standards for neuromuscular thermographic examination. Modern Medicine: supplement. 1986; 1: 5-7.
[8] Anbar M, Gratt BM, Hong D. Thermology and facial telethermography. Part I: history and technical review. Dento maxillofac Radiol. 1998; 27: 61-67.
[9] Anbar M. Fundamentals of computerized thermal imaging. In: Anbar M. Quantitative Dynamic Telethermography in Medical Diagnosis. CRC Press: Boca Raton. 1994, pp 99-131.
[10] Anbar M. Dynamic area telethermometry: a new field in clinical thermology: Part II. Medical Electronics. 1994; 147: 73-85.
[11] Anbar M. Dynamic area telethermometry and its clinical applications. SPIE Proc. 1995; 2473: 312-331
[12] Gratt BM, Anbar M. Thermology and facial telethermography: Part II: Current and future clinical applications in dentistry. Dento maxillofac Radiol. 1998; 27: 68-74.
[13] Ongole R, Praveen BN. Chapter 21- Specialized imaging techniques. In: Clinical manual for Oral Medicine and Radiology. Jaypee Brothers, New Delhi. 2007, pp 439-441.
[14] Gratt BM, Sickles EA. Electronic facial thermography: an analysis of asymptomatic adult subjects. J Orofacial Pain. 1995; 9: 255-265.
[15] Blaxter K. Energy exchange by radiation, convection, conduction, and evaporation. In: Energy Metabolism in Animals and Man Cambridge Univ. Press: New York, 1989: pp 86- 99.
[16] Blaxter K. The minimal metabolism. In: Energy Metabolism in Animals and Man. Cambridge Univ. Press: New York, 1989, pp 120-146.
[17] Gratt BM, Graff-Radford SB, Shetty V, Solberg WK, Sickles EA. A six-year clinical assessment of electronic facial thermography Dentomaxillofac Radiol. 1996; 25: 247 -255.
[18] Gratt BM, Sickles EA. Thermographic characterization of the asymptomatic TMJ. J Orofacial Pain. 1993; 7: 7-14.
[19] Gratt BM, Sickles EA, Ross JB. Thermographic characterization of an intemal derangement of the temporomandibular joint. J Orofacial Pain. 1994; 8: 197-206.
[20] Gratt BM, Sickles EA, Wexler CA. Thermographic characterization of osteoarthrosis of the temporomandibular joint. J Orofacial Pain. 1993; 7: 345-353.
[21] McBeth SA, Gratt BM. A cross-sectional thermographic assessment of TMJ problems in orthodontic patients. Am J Orthod Dentofac Orthop. 1996; 109: 481-488.
[22] Cummings M, Biagioni P, Lamey PJ, Burden DJ. Thermal image analysis of electrothermal debonding of ceramic brackets: an in vitro study. European Journal of Orthodontics. 1991; 21: 111-118.
[23] Carson J, Rider T, Nash D. A Thermographic Study of Heat Distribution during Ultra-Speed Cavity preparation. J Dent Res. 1979; 58; 16-81.
[24] Gratt BM, Shetty V, Saiar M, Sickles EA. Electronic thermography for the assessment of inferior alveolar nerve deficit. Oral Surg Oral Med Oral Pathol. 1995; 80: 153-160.
[25] Gratt BM, Sickles EA, Shetty V. Thermography for the clinical assessment of inferior alveolar nerve deficit: A pilot study. J Orofacial Pain. 1994; 8: 369- 374.
[26] Shetty V, Gratt BM, Flack V. Thermographic assessment of reversible inferior alveolar nerve deficit. J Orofacial Pain. 1994; 8: 375-383.
[27] Emmanouil DE, Quock RM. Advances in understanding the actions of nitrous oxide. Anesth Prog. 2007; 54(1):9-18.
[28] Cohen EN, Brown BW Jr, Bruce DL, et al. A survey of anesthetic health hazards among dentists. JADA. 1975; 90(6):1291-1296.
[29] McGlothlin JD, Crouch KG, Mickelsen RL. Control of nitrous oxide in dental operatories. Cincinnati: National Institute for Occupational Safety and Health; U.S. Department of Health and Human Services (NIOSH) publication.1994; 94-129.
[30] Krajewski W, Kucharska M, Pilacik B, et al. Impaired vitamin B12 metabolic status in healthcare workers occupationally exposed to nitrous oxide. Br J Anaesth. 2007;99(6):812-818.
[31] Myles PS, Chan MT, Leslie K, Peyton P, Paech M, Forbes A. Effect of nitrous oxide on plasma homocysteine and folate in patients undergoing major surgery. Br J Anaesth. 2008; 100(6):780-786.
[32] ADA Council on Scientific Affairs; ADA Council on Dental Practice. Nitrous oxide in the dental office. JADA. 1997; 128(3):364-365.
[33] Rademaker MA et al. Evaluation of Two Nitrous Oxide Scavenging systems Using Infrared Thermography to Visualize and Control Emissions. J Am Dent Assoc. 2009; 140; 190-199.
[34] Biagioni PA, Longmore RB, McGimpsey JG, Lamey PJ. Infrared thermography. Its role in dental research with particular reference to craniomandibular disorders. Dentomaxillofac Radiol. 1996; 25: 119-124.
[35] Friedlander AH, Gratt BM. Panoramic dental radiography and thermography as an aid in detecting patients at risk for stroke. J Oral Maxillofac Surg. 1994; 52: 1257- 1262.
[36] Sudhakar S, Bina kayshap, Sridhar reddy P. Thermography in dentistry-revisited. Int J Biol Med Res. 2011; 2(1): 461-465

Wednesday, April 15, 2015

Contact-free infrared thermography for assessing effects during acupuncture: a randomized, single-blinded, placebo-controlled crossover clinical trial.

Acupuncture:

Anesthesiology. 2009 Sep;111(3):632-9.

Contact-free infrared thermography for assessing effects during acupuncture: a randomized, single-blinded, placebo-controlled crossover clinical trial.

Agarwal-Kozlowski K, Lange AC, Beck H. Center for Palliative Care and Pain Management, Doerenberg Medical Center, Bad Iburg, Germany.

BACKGROUND:
Although evidence of its effects is tentative, acupuncture has long been used in the treatment of
multiple maladies. So far, it has not been possible to discriminate the effects of the venue from
specific results of needling itself, thus physicians merely depend on patients' statements. The
authors investigated the efficacy of infrared thermography in distinguishing response to true
acupuncture as compared to nonacupoint cutaneous and muscular needling (sham or minimal
acupuncture), as well as without manipulation.

METHODS:
Thermographic imaging was performed in 50 healthy volunteers randomly assigned to four
groups: Acupuncture of Hegu (LI 4), needling of a cutaneous and a muscular point where no
acupuncture point has been described yet, and without manipulation. In a crossover protocol,
each proband completed all four arms of the protocol in a random order. Infrared thermograms
were gathered at defined points in each group.

RESULTS:
A significant increase in surface temperature occurred within 2 min after needling the
acupuncture point Hegu (from 30.1 +/- 2.7 degrees C [SD] to 31.2 +/- 3.0 degrees C and to 31.9
+/- 2.5 degrees C after 10 min, P < 0.001), whereas needling of the cutaneous and muscular
point, as well as without any manipulation resulted in a decrease of temperature in the monitored
area.

CONCLUSION:
Contact-free infrared thermographic imaging is a reliable and easy-to-handle tool to
distinguish between needling at Hegu and needling of a nonacupoint ("sham"
acupuncture).

Wednesday, April 8, 2015

Thermography and Return to Play Decisions
Dr. William A. Sands

Inflammation is a consistent indicator of injury and ongoing healing. Thermal imaging is
used for the characterization of inflammation. Thermal imaging can be used to monitor
the location, status, and progress of an injury by comparisons of the size of the injured
area and its temperature.

• Injuries foster a number of decisions that suffer from uncertainty, yet may require firm commitment, vigilance, and follow-through to resolve the injury. Uncertainty arises from variations in diagnoses, healing capacities, pain tolerance, effectiveness of healing modalities and medications, and
psychological support (1,3,6,8,9). Those who treat athletic injuries, coaches, athletes, and parents are often faced with return to play decisions that are wrought with pitfalls due to the lack of pertinent information regarding the athlete’s current injury state, his/her current performance status, and the risks and benefits of returning to activity. However, thermography technology may reduce the uncertainty.

Thermography involves the use of a special camera that can detect a portion of the
electromagnetic spectrum that lies just below the region of visible light–infrared light. Infrared light is the product of heat; all objects show heat, unless the object is at the temperature of absolute zero.

People are terrific heat sources. The heat that people produce is variable depending on the region of the body, metabolism, and other factors. One of the greatest sources of heat is that due to inflammation. Inflammation is derived from the same word as “flame” and accompanies all types of pain and injury. Inflammation is detectable as a heat source in the injured athlete, particularly when the temperature of the inflamed area is higher than that of the surrounding skin.

One of the interesting properties of inflammation and the detection of the heat produced by inflamed tissues is that even deep tissues often show a “signature” of heat in the overlying skin. In athletic injury, inflammation is usually reasonably close to the skin surface and easily detectable by thermal imaging equipment (2,4,5,10,11,12).

Thermal imaging has been used for injury and disease detection, malingering, and other
characteristics (2,4,5,7,10,11). Recent experience has shown that thermal imaging can be
used to assess the status and change of active inflammation that can reduce the
uncertainty regarding return to play decisions. Pain and inflammation have always been
coincident; thermal imaging can assess the presence of inflammation and thus provide
information about the progress of injury healing.

Monitoring the healing and recovery from injury with thermal imaging can help determine
whether an athlete’s injury has ceased the active inflammation period. Clearly, if
inflammation is still present, return to play should be postponed, further medical
consultation is needed, and increased vigilance and caution are merited. Injuries that have
become mostly or completely pain-free have been monitored with thermal imaging and the
injuries have shown a return of inflammation after premature return to play.

In conclusion, thermal imaging can provide a window into the world of injury recovery and
reduce the uncertainty involved in return to play decisions. Thermal imaging equipment
has been dropping in price for years and is available in a variety of camera-types and
configurations. Those concerned with return to play decisions are encouraged to consider
thermal imaging.

Wednesday, February 18, 2015

Infrared thermography in the detection of brown adipose tissue in humans.



Infrared thermography in the detection of brown adipose tissue in humans.

Author information

Abstract

PET-CT using 18F-FDG is employed for detecting brown adipose tissue (BAT) in humans. Alternative methods are needed because of the radiation and cost of PET-CT imaging. The aim was to evaluate the accuracy of infrared thermography (IRT) in detecting human BAT benchmarked to PET-CT imaging. Seventeen individuals underwent a total of 29 PET-CT scans, 12 of whom were studied twice, after 2 h of cold stimulation at 19°C, in parallel with measurement of skin temperatures overlying the supraclavicular (SCV) fossa and the lateral upper chest (control), before and after cold stimulation. Of the 29 scans, 20 were BAT positive after cold stimulation. The mean left SCV temperature tended to be higher in the BAT-positive group before and during cooling. It was significantly higher (P = 0.04) than the temperature of the control area, which fell significantly during cooling in the BAT-positive (-1.2 ± 0.3°C, P = 0.002) but not in the negative (-0.2 ± 0.4°C) group. The temperature difference (Δtemp) between left SCV and chest increased during cooling in the BAT-positive (1.2 ± 0.2 to 2.0 ± 0.3°C, P < 0.002) but not in the negative group (0.6 ± 0.1 to 0.7 ± 0.1°C). A Δtemp of 0.9°C conferred a positive predictive value of 85% for SCV BAT, superior to that of SCV temperature. The findings were similar on the right. In conclusion, the Δtemp is significantly and consistently greater in BAT-positive subjects. The Δtemp quantified by IRT after 2-h cooling shows promise as a noninvasive convenient technique for studying SCV BAT function.


Introduction

The recent years have seen a dramatic resurgence of interest in brown adipose tissue (BAT) in humans. Following the discovery of FDG‐avid depots in the supraclavicular and neck regions of humans undergoing Positron Emission Tomography (PET)‐CT scanning, investigations moved rapidly to histological confirmation of these depots as BAT (Zingaretti et al. 2009; Lee et al. 2011b) and then to define its contribution to energy expenditure. Indeed, efforts have now turned to exploring BAT as a novel therapeutic target in human metabolic disease.
Currently, PET‐CT is the gold standard method for the detection of BAT. However, PET‐CT has a number of limitations, including cost, radiation exposure, and duration of the procedure (Nedergaard and Cannon 2010; Lee et al. 2013). Diagnostic PET‐CT scans expose substantial radiation to the subject (Huang et al. 2009). While radiation exposure can be minimized in scans performed for research purposes, it will continue to limit the use of PET‐CT particularly for healthy volunteers. Furthermore, the reproducibility of PET‐CT imaging is poor (Lee et al. 2010) because of the susceptibility to changes and differences in scanning temperature and seasonal variations in temperature (Cohade et al. 2003; Au‐Yong et al. 2009; Zukotynski et al. 2009; Ouellet et al. 2011). Therefore, there is a need to develop other methods to investigate BAT physiology.
Because of the thermogenic properties of BAT, thermal imaging is a potential method for detecting BAT and studying its function. Using infrared thermography (IRT), we have previously reported a significantly higher skin temperature in the region overlying the supraclavicular (SCV) fossa than the mediastinal (MED) region in 87 individuals (Lee et al. 2011a). In one subject, this temperature difference became more pronounced following a meal ingestion and cold exposure, both known stimulants of BAT activity. Temperature increases within the supraclavicular region in response to cold exposure have also been confirmed with thermography in a recent study (Symonds et al. 2012). However, studies directly comparing and validating the results of IRT with PET‐CT imaging have not been published. The aim of this study was to assess the accuracy of IRT to predict the presence of BAT as benchmarked against PET‐CT imaging specifically to establish reproducibility, sensitivity, and specificity.

Subjects and Methods

Subjects

Seventeen healthy subjects (12 men and five women) were studied after obtaining written informed consents. The mean age (±SD) was 36 ± 8 years and BMI was 25.4 ± 5.9 kg/m2. Subjects were recruited to undergo PET‐CT scanning in a study to optimize conditions for the detection of BAT. In all subjects, PET‐CT scans were undertaken after a 6‐h fast and none had fasting hyperglycemia. The study was approved by the Human Research and Ethics Committee of Metro South Health Service.

Methods

All subjects underwent a 2‐h period of cooling at 19°C in an air‐conditioned room prior to intravenous administration of 18F‐FDG. Of the 17 subjects, 12 subjects were studied twice 2–3 weeks apart. This was done to determine the reproducibility of BAT detection under the 2‐h precooling conditions, collectively providing a total of 29 scans for analysis. We previously reported that the reproducibility of BAT detection under ambient conditions for routine diagnostic PET scanning (for malignancy staging) is low, being less than 15% (Lee et al. 2010). We treated each measurement as separate cases because the brown fat activity may vary within the same individual between different occasions of scanning. It was therefore important to determine whether the IRT measurements correspond to BAT activity on PET scans on every occasion.

PET‐CT imaging

All subjects were seated and rested comfortably in a quiet room during the procedure. PET imaging was undertaken at 1 h after intravenous injection of 75 MBq (2 mCi) of 18F‐FDG on a Biograph mCT 128 (Siemens Healthcare, Erlangen, Germany) equipped with time‐of‐flight electronics, in three‐dimensional list mode for 30 min in one bed position covering the skull base to the aortic arch. Noncontrast low‐dose CT (80 mAs) was subsequently performed for attenuation correction and localization of FDG‐avid sites. PET and CT image datasets were reconstructed in axial, coronal, and sagittal planes with a slice thickness of 4 mm. Images were interpreted by a dual‐qualified radiologist/nuclear physician using syngo.via software (Siemens Healthcare). BAT volume (in cm3) was quantified for right SCV and left SCV areas by autocontouring of FDG uptake above a set threshold (SUVmax 1.5) that show fat attenuation on CT. PET‐CT images for BAT were classified as “BAT Positive” or “BAT Negative” accordingly.

Infrared thermography

Subjects were seated in the upright position in an arm chair with head positioned in a neural position and the subject looking straight ahead. The upper torso from the chest area to neck region was exposed. A thermal imaging camera (FLIR B425, 3.1Mpixel, FLIR Systems Australia Pty Ltd, Melbourne, Vic., Australia) was used to acquire images of the anterior neck and upper chest region. The camera was positioned at the level of the neck 1 m from the subject's face. IRT was performed on all subjects at baseline ambient room temperature and then at 60 and 120 min during cooling at 19°C prior to PET‐CT scanning.
Using FLIR Research IR Professional Analyzing Software (Version 1.2, Wilsonville, OR), skin temperatures overlying the SCV fossa bilaterally and an area in the upper chest just lateral to the sternum approximating the second intercostal space (control) were determined for each image. Analyses were performed for both right and left SCV regions (Fig. ​(Fig.11).
Figure 1.
Mean (±SE) temperatures over the left (L) and right (R) supraclavicular areas (upper panel) and the anterior chest (lower panel) over 2 h of cooling at 19°C in an air‐conditioned room in subjects with positive and negative PET ...
For thermal analysis, the camera was set to fusion mode which displays a fusion of digital and thermal images. The emissivity was set to 0.98 for skin as detailed by the FLIR operations manual.
Temperature measurement of the SCV region was performed as follows. A circle, 2 cm margins, centered immediately above the midclavicle was selected for temperature analysis. In instances where there is a temperature gradient peak in the SCV fossa, there is a color gradation of increasing temperature from the periphery to the middle of the area. A target region of measurement was set around the first temperature contour gradient from the periphery and the highest temperature within this target area was recorded for later analysis. In images where no temperature gradient is apparent, an area above the midclavicle corresponding to the SCV fossa was selected for temperature measurement. This procedure was repeated for the chest control area. There was no difference in skin temperatures of the chest control areas on the left and the right. Analyses were undertaken using only the chest control readings on the left. iButtons are available as a means of recording skin temperature directly. iButtons were not used in this study because preliminary evaluation revealed excellent concordance between the camera and iButtons readings.

Statistical analysis

Statistical analysis was performed using SPSS version 21 (SPSS Inc., Chicago, IL, USA). Data are reported as mean ± SEM. The unpaired t‐test was used to compare data between the BAT‐positive and BAT‐negative groups. Two‐way repeated measures ANOVA was employed to determine whether temperatures changed significantly during cooling and whether this was influenced by PET status. Pearson correlation analysis was employed to test the relationships between different variables. Differences in temperatures during cooling between PET‐positive and PET‐negative groups were determined by two‐way ANOVA. The sensitivity and specificity of IRT were determined by ROC analysis. A P value <0.05 was considered significant.

Results

Of the 29 scans performed after precooling, 20 were positive for BAT and nine were negative (Table 1). Of the 12 subjects who were studied twice, 10 had concordant scans (seven repeat positive, three repeat negative scans) while two subjects had discordant scans. 15 participants had repeat thermography images taken twice within 1 min on at least one occasion. The mean difference in recorded temperature between two images for 15 subjects was 0.06 ± 0.01°C with a CV of 0.009%.
Table 1.
Clinical characteristics of subjects categorized to BAT status as defined by PET‐CT imaging. Data are expressed as Mean ± SEM

SCV temperature

At baseline before cooling, mean left SCV temperature in the PET positive tended to be higher than that in the PET‐negative group (32.8 ± 0.3 vs. 31.5 ± 0.5, P =0.055) (Fig. ​(Fig.1).1). A similar trend was present on the right (32.4 ± 0.3 vs. 31.4 ± 0.6, P =0.06).
After 2‐h cooling, the mean SCV temperature remained higher in PET‐positive than PET‐negative group on both sides (left 32.3 ± 0.3 vs. 31.3 ± 0.5, P =0.08 and right 31.6 ± 0.3 vs. 31.0 ± 0.5, P =0.1), but the differences did not reach statistical significance nor did the temperature change significantly over the 2‐h cooling period (two‐way ANOVA) (Fig. ​(Fig.11).
Comparing left and right SCV temperatures, the mean skin temperature after 2‐h cooling overlying the left SCV was significantly higher than that on the right for both PET‐positive (32.3 ± 0.3 vs. 31.6 ± 0.3°C, P <0.001) and PET‐negative groups (31.3 ± 0.5 vs. 31.0 ± 0.5°C, P <0.01).
The mean BAT volume in the left SCV fossa was not significantly different to that of the right on the PET scan. SCV temperatures did not correlate significantly with SCV BAT volume.

Control chest temperature

At baseline before cooling, there was no difference in the mean chest temperatures between PET‐positive and PET‐negative groups (31.2 ± 0.4 vs. 30.9 ± 0.4) (Fig. ​(Fig.11).
After cooling, the mean chest temperature fell significantly by 1.2 ± 0.3°C (p = 0.002) in the PET‐positive but not in the PET‐negative (0.2 ± 0.4°C) group (Fig. ​(Fig.1)1) and the difference was significant between the groups (P =0.04). As cooling induced a greater fall in chest than in SCV temperatures, this resulted in a rise in the magnitude of temperature difference ([increment]temp) between the two sites.

Temperature difference between SCV and control chest areas ([increment]temp)

At baseline before cooling, in the BAT‐positive group, the mean SCV temperatures on both sides were significantly higher than the control chest temperature (Fig. ​(Fig.1).1). Similarly, in the BAT‐negative group, the mean SCV temperatures on both sides were also significantly higher than mean chest temperature. [increment]temp was greater in the BAT positive than in the negative group on the left (1.2 ± 0.2 vs. 0.6 ± 0.1°C, P =0.04) and right sides (1.0 ± 0.2 vs. 0.5 ± 0.01°C, P =0.04) (Fig. ​(Fig.2).2). The [increment]temp was significantly greater on the left than on the right side (P =0.004) in the BAT‐positive group.
Figure 2.
Upper panel shows Individual paired plots in PET‐positive (left panels) and PET‐negative (right panels) subjects studied before and after 2 h of cooling. The temperature difference ([increment]temp) between supraclavicular (left and right) ...
After cooling, [increment]temp between SCV and chest areas remained significantly greater in the BAT positive than the negative group on the left (2.1 ± 0.3 vs. 0.7 ± 0.1°C, P =0.002) and the right side (1.4 ± 0.3 vs. 0.4 ± 0.1°C, P =0.02). Moreover, for the 20 positive scans, the SCV BAT volume was significantly correlated with [increment]temp which was stronger on the left side (r = 0.57, P =0.004) than on the right (r = 0.49, P =0.02).
[increment]temp on the left rose significantly (1.2 ± 0.2 to 2.1 ± 0.3 °C; P = 0.04) in the BAT‐positive group but not in the BAT‐negative (0.6 ± 0.1 to 0.7 ± 0.1°C, P = 0.6) group (Fig. ​(Fig.2)2) with cooling. The change in [increment]temp on the right was similar, increasing in the BAT‐positive (1.0 ± 0.2 to 1.4 ± 0.3°C, P = 0.09) but not in the BAT‐negative (0.5 ± 0.1 to 0.4 ± 0.1°C) group. The [increment]temp change was greater on the left than right side throughout cold stimulation in the BAT‐positive group (P = 0.01). Figure 2 shows paired plots of [increment] temp on the right and left sides for each of the assessments in PET‐positive and PET‐negative scans.
Representative PET/CT scans and corresponding thermograms before and after cooling from two PET‐positive and a PET‐negative subject are shown in Figure 3. For the two positive scans, SCV temperatures are higher than the adjacent lateral areas before and after cooling. Note the fall in chest temperature after cooling. In the PET‐negative subject, the temperature in the SCV fossa is similar to the adjacent lateral area. There is no change in chest temperature after cooling.
Figure 3.
Representative PET‐CT and thermography images before and after 120‐min cooling for (A) two BAT‐positive subjects and (B) one BAT‐negative subject. In A, the thermograms for both PET‐positive subjects indicate that ...

ROC analysis

Before cooling, ROC analysis revealed that an optimal discriminant [increment]temp of >0.9 conferred a sensitivity of 77% and specificity of 78% on the left for a positive PET scan (Table 2). After 2 h of cooling, sensitivity increased to 87% with specificity unchanged. On the right, before cooling a Δtemp of ≥ 0.9°C conferred a sensitivity and specificity figures of 59% and 89% and after cooling, 68% and 78%, respectively. The sensitivities and specificities of SCV temperatures on the left and right were inferior to those of the corresponding [increment]temps. The corresponding positive and negative predictive values displayed in Table 2 show that the [increment]temp of 0.9 on the left side at 2 h of cooling confers a positive predictive value of 85% and negative predictive value of 77% for a positive PET scan. The sensitivity, specificity, and predictive values for SCV temperatures were inferior to corresponding [increment]temps regardless of the side of analysis.
Table 2.
Sensitivity and predictive value of infrared thermography for a positive PET/CT scan

Discussion

IRT is an established and accepted technique for studying BAT function in small animals (Mccafferty 2007; Marks et al. 2009; Gilbert et al. 2012; Warner et al. 2013). Studies employing IRT to assess BAT activity in humans are beginning to emerge (Lee et al. 2011a; Symonds et al. 2012). However, the predictive value for detecting BAT by IRT in humans has not been rigorously assessed. This study investigated the usefulness of IRT as a tool for detecting BAT in humans by validating thermal imaging to that of positive PET‐CT imaging. During controlled cold stimulation in an air‐conditioned room, the mean skin temperature over the SCV fossa tended to be higher in the BAT‐positive group. Mean SCV temperatures were consistently higher than that over the chest in both BAT‐positive and BAT‐negative groups. The temperature difference between SCV and chest areas was significantly greater in the BAT‐positive group, correlated significantly with BAT volume and was consistently greater on the left. This temperature difference increased during cooling, an effect resulting from a fall in chest temperature rather than a rise in SCV temperature. The [increment] temp after cooling correlated significantly with BAT volume. The temperature difference was a better predictor of PET status than SCV temperature.
The observation that BAT‐positive subjects exhibited a fall in chest temperature compared to BAT‐negative counterparts is intriguing. It is conceivable that skin temperature over the chest provides afferent sensory input for the central activation of the SNS required to stimulate BAT function. Thus, a lower chest cutaneous temperature triggers a greater activation of BAT to maintain SCV temperature at a level which might have been lower in the absence of BAT activity. It is possible that the amount of body fat influenced the magnitude of the fall in chest temperature during cooling. Diminished thermal insulation could trigger the SNS, simultaneously stimulating BAT activity and causing peripheral skin vasoconstriction. As we did not measure body composition, we are unable to determine whether the proportion of body fat was lower in PET‐positive subjects.. Several studies have reported that body mass index is a negative predictor of BAT activity (Lee et al. 2013). In this study, mean body mass index tended to be lower among the PET‐positive subjects. Regardless of the mechanism(s), we have observed, in BAT‐positive subjects, higher SCV temperature, a greater skin temperature difference between BAT‐positive and ‐negative sites that is significantly correlated with the mass of BAT. These findings provide strong evidence that BAT in adult human is thermogenic and detectable by IRT.
We undertook a systematic ROC analysis of the impact of cooling on the value of SCV temperature and the [increment]temp in predicting BAT as identified by PET/CT. It is well established that cold stimulation enhances the detection and activity of BAT as assessed by PET‐CT imaging in humans. The rate of BAT detectability increases from 5–10% at ambient temperature to over 90% after cold stimulation (Lee et al. 2011b), a change equating to an increase in BAT activity of 10‐ to 15‐fold (Virtanen et al. 2009). SCV temperature was far inferior to [increment] temperatures and cooling had little effect because SCV temperatures did not change. In contrast, cooling enhanced the predictive value of [increment]temp on both left and right sides. Like PET‐CT, the diagnostic power of IRT is enhanced by cooling.
Another interesting observation was the consistently higher SCV temperature on the left than on the right, regardless of BAT status, and a greater temperature difference on the left between SCV and chest areas in BAT‐positive subjects. We observed no differences in SCV BAT mass between the sides nor asymmetry in the FDG uptake in those with positive scans suggesting that the lateralization is unlikely to be BAT related. The cooling technique is also unlikely to have had much bearing; subjects sat in an air‐conditioned room where cooling was spread evenly. Moreover, this temperature difference is evident before cooling and maintained throughout. We speculate that higher SCV skin temperature on the left arises from the unique vascular anatomy from a capacious brachiocephalic vein on the left.
IRT has several advantages. The procedure is convenient as it can be undertaken within minutes, unlike PET‐CT which requires a postinjection and scanning time of at least 2 h. Importantly, there is no radiation exposure with IRT, whereas for PET‐CT using a standard FDG dose, the radiation from a single study for oncological indications far exceeds radiation safety limits for investigative studies in normal subjects. Another useful application for IRT is in the monitoring of changes in BAT activity over minutes or hours that cannot be done with PET‐CT, which is restricted to a single time domain of capture over 1 h. In that regard, IRT offers considerable advantages as a safer and more flexible tool for studying BAT function and activity.
IRT conferred a probability of greater than 80% in predicting BAT. While promising, we caution against using IRT independent of PET‐CT imaging until more evaluations are published. At this stage, we propose that it serves as a screening tool for selecting subjects for regulatory studies of BAT function in whom the presence of significant BAT activity is initially confirmed by PET‐CT imaging. A baseline of PET positivity brings specificity to the interpretation of changes in temperature difference between the neck and chest as changes in BAT activity.
One of the limitations of IRT is that it is confined to studying BAT that is located superficially, particularly the SCV fossa. It is unlikely that thermogenicity of BAT located in deeper areas can be detected by IRT. Therefore, the study of BAT activity in humans by IRT is restricted to superficial BAT depots. Our study population is small and consisted of a heterogeneous group of individuals of varying age and BMI undergoing simultaneous PET‐CT scanning after cold stimulation by air conditioning. Future studies comprising larger numbers are required to provide more information on the value of IRT in the evaluation of BAT in humans.
This is the first study investigating the utility of IRT for detecting BAT referenced to PET‐CT. Our evaluation provides strong evidence that IRT is a promising noninvasive technique for the detection of BAT in the SCV region. The discriminant measure is the difference in skin temperatures between the SCV and the lateral chest areas, and not the temperature overlying the SCV fossa after cold stimulation. The predictive value of the temperature difference is better on the left than on the right. IRT is a useful technology that may complement PET‐CT imaging in the study of BAT in humans.