Cardiovasc Intervent Radiol 1998 Nov-Dec;21(6):481-6
Can rotational atherectomy cause thermal tissue damage? A study of the potential heating and thermal tissue effects of a rotational atherectomy device.
Gehani AA, Rees MR; Cardiac Research Unit, Killingbeck Hospital, Leeds, United Kingdom.
PURPOSE: Thermal tissue damage (TTD) is customarily associated with some lasers. The thermal potential of rotational atherectomy (RA) devices is unknown. We investigated the temperature profile and potential TTD as well as the value of fluid flushing of an RA device.
METHODS: We used a high-resolution infrared imaging system that can detect changes as small as 0.1 degree C to measure the temperature changes at the tip of a fast RA device with and without fluid flushing. To assess TTD, segments of porcine aorta were subjected to the rotating tip under controlled conditions, stained by a special histochemical stain (picrisirius red) and examined under normal and polarized light microscopy.
RESULTS: There was significant heating of the rotating cam. The mean "peak" temperature rise was 52.8 +/- 16.9 degrees C. This was related to rotational speed; thus the "peak" temperature rise was 88.3 +/- 12.6 degrees C at 80,000 rpm and 17.3 +/- 3.8 degrees C at 20,000 rpm (p < 0.001, t-test). Fluid flushing at 18 ml/min reduced, but did not abolish, heating of the device (11.8 +/- 2.9 degrees C). A crater was observed in all segments exposed to the rotating tip. The following features were most notable: (i) A zone of "thermal" tissue damage extended radially from the crater reaching adventitia in some sections, especially at high speeds. This zone showed markedly reduced or absent birefringence. (ii) Fluid flushing of the catheter reduced the above changes but increased the incidence and extent of dissections in the media, especially when combined with high atherectomy speeds. (iii) These changes were observed in five of six specimens exposed to RA without flushing, but in only one of six with flushing (p < 0.05). (iv) None of the above changes was seen in control segments.
CONCLUSION: RA is capable of generating significant heat and potential TTD. Fluid flushing reduced heating and TTD. These findings warrant further studies in vivo, and may influence the design of atherectomy devices.
Showing posts with label thermal tissue damage. Show all posts
Showing posts with label thermal tissue damage. Show all posts
Wednesday, July 29, 2015
Can rotational atherectomy cause thermal tissue damage? A study of the potential heating and thermal tissue effects of a rotational atherectomy device
Labels:
adjunct,
atherectomy,
Digital,
injury,
IRT,
MII,
MTI,
physiology,
RA,
rotational atherectomy,
temperature,
thermal tissue damage,
thermography camera,
TTD
Friday, September 7, 2012
Thermal imaging
– a hotspot for the future?: A case report
Ronald
J Cook, Shobhan Thakore and Neil M Nichol
Accident
and Emergency Department, Ninewells Hospital and Medical School, Dundee
DD1 9SY, UK
Case
report:
A
6-year-old boy presented to accident and emergency with his mother complaining
of a painful right elbow following a fall that day. He fell whilst walking up
steps and gave a history of directly striking the elbow on the step. He had not
been using the arm since. There was a recent history of a comminuted
intra-articular fracture of the proximal ulna of the same elbow, and a cast had
been removed just 5 weeks previously.
The patient was seen and examined
by an experienced A&E senior house officer. He was difficult to assess and
was complaining of pain in the entire arm. There was no swelling or deformity
and no apparent bony tenderness to the limb. He was unwilling to actively move
the elbow joint, however there was a good range of passive movement throughout
the arm and good grip strength was noted. An X-ray of the elbow was performed
and no bony injury or effusion of the elbow joint was apparent. The child was
treated for a soft tissue injury of the elbow, advised regular analgesia and
discharged.
The patient
represented two days later complaining of persistent pain to the arm. He was
now localising pain to the wrist and there was a corresponding area of
tenderness over the distal radius. A thermal image was taken of the limb using
a hand held FTI Mv thermal imager interfacing with LIPS Mini PC software. The
image identified an obvious “hotspot” corresponding to the area of tenderness
over the distal radius, which clearly differed from a thermal image of the
normal wrist. Subsequent X-ray of the wrist revealed an undisplaced
greenstick fracture of the distal radius. The child was treated with a plaster
cast, referred to the orthopaedic fracture clinic and made an uneventful
recovery.