Tuesday, December 18, 2012


I mentioned Digital Infrared Imaging to my doctor and was told that the procedure is outdated and useless, is this true?
Unfortunately, many physicians either do not know about this technology or are knowledgeable about a single poorly performed (with regards to DII) research study; the BCDDP (Breast Cancer Detection Demonstration Project). The BCDDP was a large study done in the 1970’s that collected data from many centers around the United States. Three methods of breast cancer detection were studied: physical examination, mammography, and thermography.
With regards to thermography, the BCDDP was seriously flawed in six critical areas.
  1. Completely untrained technicians were used to perform the scans.
  2. The study used radiologists who had no experience or knowledge in reading infrared images.
  3. No standardized reading protocol had yet been established for infrared imaging.
  4. Proper laboratory environmental controls were completely ignored. In fact, many of the research sites were mobile trailers with extreme variations in internal temperatures.
  5. Low resolution industrial grade infrared imagers were used.
  6. The initial premise of the study was flawed: "A negative thermogram would preclude the need for a mammogram." A fuctional imaging test (thermography) cannot replace a structural imaging procedure (mammography). These two imaging tools complement each other. Thermography is to be used in addition to mammography, not as a replacement.
Of considerable concern was the reading of the images. It wasn’t until the early 1980’s that established and standardized reading protocols were introduced. Considering these facts, the BCDDP could not have properly evaluated infrared imaging. With the advent of known laboratory environmental controls, established reading protocols, and state-of-the-art infrared technology, a poorly performed 20-year-old study cannot be used to determine the appropriateness of DII.

Friday, December 14, 2012


FEM Centre has utilized DITI for many years and we have found the Spectron IR camera and software superior to our previous equipment. The package Spectron offers has enabled us to qualitatively and quantitatively asses the rate and pattern of asymmetry of heat and vascular patterns. Due to its 307,000-pixel image capability, the quality of the image is far superior to that of the competitor. These attributes have allowed the analysis of asymmetries over a specific period by means of serial exams.

Additionally, we have found the software support from the staff exemplary and professional going beyond our expectations allowing us to provide the best possible care for our patients.

-          Joseph McWherter M.D.
FEM Centre

http://spectronir.com/testimonials

Assessment of the impact of the visual work with display monitors on the eye temperature and intraocular pressure


Assessment of the impact of the visual work with display monitors on the eye temperature and intraocular pressure.

[Article in Polish]

Source

Przychodnia Chorób Zawodowych, Instytut Medycyny Pracy im. prof. J. Nofera, Łódź. alapw@imp.lodz.pl

Abstract

BACKGROUND:

The aim of this study was to assess the impact of the visual work with display monitors on the eye surface temperature, intraocular pressure and on the eye moisturizing condition.

MATERIALS AND METHODS:

The study was conducted among 50 people working with display monitors (CRT, LCD) and without monitor. The temperature of the eye surface via thermo camera and intraocular pressure were measured, as well as Schirmer's test was performed before and after 4 h of visual work. Thermography was also performed after 1 h.

RESULTS:

The studies revealed no significant effect of all visual works in patients with normal tear secretion. Only among those with dry eye syndrome, statistically significant increase in the eye surface temperature was found and averaged 0.5 degrees C after 4 h of all visual works.

CONCLUSION:

The studies revealed that intensive visual work with CRT and LCD display monitors and without monitor causes changes in the eye surface temperature, especially after the first hour of visual work and in patients with dry eye syndrome. The results of tonometry showed that all visual works at a short distance lead to the decreased intraocular pressure, resulting from the improved aqueous humor outflow. Finally, no negative effects of the visual work with the display monitor on the eye was found. However, the appropriate duration of work and application of tear substitutes play an important role in people with the symptoms of dry eye syndrome.
PMID:
 
21452565
 
[PubMed - indexed for MEDLINE]

Coming events cast their shadows before: detecting inflammation in the acute diabetic foot and the foot in remission.

Source

Southern Arizona Limb Salvage Alliance (SALSA), College of Medicine, University of Arizona, Tucson, AZ 85724, USA.

Abstract

The incidence of diabetic foot complications, most notably wounds, is increasing worldwide. Most people who present for care of a foot wound will become infected. Globally, this results in one major amputation every 30 seconds with over 2500 limbs lost per day. Presently, clinicians assess circulation, neuropathy and plantar pressures to identify the risk of foot ulceration. Several studies have suggested prevention of foot ulcers by identifying individuals at high risk and treating for lower extremity complications. Our group has proposed several diagnostics as well as prevention strategies, especially thermography and thermometry for management of patients with diabetic foot complications. These strategies employ non-invasive assessment of inflammation for acute as well as chronic care for the foot, with the intent to prevent ulceration/re-ulceration and subsequent traumatic amputations. The authors' review some important clinical studies and ongoing research in this area, with the long-term goal to further the role of thermography and thermometry in clinical care for the diabetic foot.
Copyright © 2012 John Wiley & Sons, Ltd.
PMID:
 
22271717
 
[PubMed - indexed for MEDLINE]

Nasal airflow and thoracoabdominal motion in children using infrared thermographic video processing.

Source

Department of Pediatric Anesthesiology, La Paz Children's University Hospital, Paseo de la Castellana 261, Madrid, Spain. luisgoldman@terra.es

Abstract

The assessment of apnea and asynchronous breathing requires the application of a facemask connected to a pneumotachograph and inductive transducer bands placed around the chest wall. These contact devices may alter the breathing pattern and are difficult to implement, especially in infants and children. This study validates a contactless image-processing system that simultaneously retrieves breath-related thermal variations from nasal, ribcage, and abdomen regions of interest (ROI) from infrared thermographic video recordings of children. Thermographic videos were obtained in 17 supine, spontaneously breathing unsedated children (0.33-13.75 years), including 8 patients with respiratory pathology. Representative thermographic signals were obtained from each ROI on a frame-by-frame basis. Cronbach's Alpha reliability coefficient assessed the correlation between control nasal pressure period, the visually scored respiratory rate and the fundamental period in the frequency domain of thermographic signals. A cross-correlation function calculated the time delay and the phase angle between ribcage and abdomen variability. A Cronbach's Alpha value of 0.976 (0.992-0.944 95% CI) suggests a small-scale measurement error between thermographic and control periods. The ribcage-abdomen time delay in children with respiratory disease (-0.42 ± 0.707 sec) significantly differed from healthy children (0.22 ± 0.426 sec, P = 0.0125). This novel system reliably acquired time-aligned nasal airflow and thoracoabdominal motion estimates without relying on attached sensor performance and detected asynchronous breathing in pediatric patients.
Copyright © 2011 Wiley Periodicals, Inc.
PMID:
 
22009760
 
[PubMed - indexed for MEDLINE]

www.spectronir.com/testimonials

Monday, November 19, 2012

The influence of fatigue on muscle temperature.


 2012;18(2):233-43.

The influence of fatigue on muscle temperature.

Source

Central Institute for Labour Protection, National Research Institute, Poland. pabar@ciop.pl

Abstract

The aim of the study was to investigate the possibility of using infrared (IR) thermography for assessing muscle fatigue during low effort. Three tests at constant levels of load 5, 15 and 30% of maximum voluntary contraction (MVC) lasting 5 min each were performed on a group of 10 men. Temperature and electromyographic (EMG) signal were registered from biceps brachii (BB). Analysis focused on the influence of load on the values and changes in time of muscle temperature. Correlations between temperature and EMG parameters (RMS, MPF and MF) were also analysed. Constant load sustained during the tests resulted in an increase in the temperature of BB. There were statistically significant correlations between temperature and EMG parameters for most subjects. Results of the study suggest that IR thermography can be an alternative or supplementary method for assessing muscle fatigue at low levels of contraction.
PMID:
 
22721541
 
[PubMed - indexed for MEDLINE]


Click below to find out how you can own a system of your own:
www.spectronir.com

Thursday, November 15, 2012

Application of medical thermography to the diagnosis of Frey's syndrome.


Head Neck. 1997 Mar;19(2):143-7.
Application of medical thermography to the diagnosis of Frey's syndrome.
Source
Department of Plastic and Reconstructive Surgery, Kinki University Hospital, Osaka, Japan.
Abstract
BACKGROUND:
In Frey's syndrome, the secretory parasympathetic fibers of the parotid gland are thought to communicate with the sympathetic nerve fibers of sweat glands and blood vessels of the skin following parotidectomy. Miscommunication results in subjective gustatory sweating and facial flushing, which appear early with postoperative mastication. In this study, we compared the efficacy of medical thermography to the Minor's starch-iodine test to determine the presence of gustatory sweating in Frey's syndrome.
METHODS:
Patients were considered to have Frey's syndrome if signs of gustatory sweating and localized skin flushing of the parotid region were present. In four patients who had undergone unilateral parotidectomy, gustatory sweating and facial flushing were present after gustatory stimulation, and the presence of Frey's syndrome was confirmed with Minor's starch test in all patients. Infrared thermography was then performed, and the same area measured. The contralateral side served as an internal control for each patient.
RESULTS:
Before gustatory stimulation, the isothermal pattern of the diseased side and the nonoperative side was similar. Stress thermographyusing a sialogogue (lemon, 3 mL) showed a cold spot at the operative site in all four patients with Frey's syndrome. The contralateral nonoperative side showed normal skin temperature distribution in all patients. Minor's test was positive in all patients.
CONCLUSIONS:
Thermography is a noninvasive, facile test that provides a qualitative visual analysis of the cutaneous capillary response in Frey's syndrome following parotid surgery.

www.spectronir.com

Monday, November 12, 2012


Thermatomal changes in cervical disc herniations. Zhang HY, Kim YS, Cho YE;
Department of Neurosurgery, Yongdong Severance Hospital, Yonsei College of Medicine, Seoul, Korea.
hyzhang@unitel.co.kr
Subjective symptoms of a cool or warm sensation in the arm could be shown objectively by using of
thermography with the detection of thermal change in the case of radiculopathy, including cervical disc
herniation (CDH). However, the precise location of each thermal change at CDH has not been
established in humans. This study used digital infrared thermographic imaging (DITI) for 50 controls and
115 CDH patients, analyzed the data statistically with t-test, and defined the areas of thermatomal change
in CDH C3/4, C4/5, C5/6, C6/7 and C7/T1. The temperature of the upper trunk and upper extremities of
the control group ranged from 29.8 degrees C to 32.8 degrees C. The minimal abnormal thermal
difference in the right and left upper extremities ranged from 0.1 degree C to 0.3 degree C in 99%
confidence interval. If delta T was more than 0.1 degree C, the anterior middle shoulder sector was
considered abnormal (p < 0.01). If delta T was more than 0.3 degree C, the medial upper aspect of the
forearm and dorsal aspect of the arm, some areas of the palm and anterior part of the fourth finger, and
their opposite side sectors and all dorsal aspects of fingers were considered abnormal (p < 0.01). Other
areas except those mentioned above were considered abnormal if delta T was more than 0.2 degree C (p
< 0.01). In p < 0.05, thermal change in CDH C3/4 included the posterior upper back and shoulder and the
anterior shoulder. Thermal change in CDH C4/5 included the middle and lateral aspect of the triceps
muscle, proximal radial region, the posterior medial aspect of the forearm and distal lateral forearm.
Thermal change in CDH C5/6 included the anterior aspects of the thenar, thumb and second finger and
the anterior aspects of the radial region and posterior aspects of the pararadial region. Thermal change
in CDH C6/7 included the posterior aspect of the ulnar and palmar region and the anterior aspects of the
ulnar region and some fingers. Thermal change in CDH C7/T1 included the scapula and posterior medial
aspect of the arm and the anterior medial aspect of the arm. The areas of thermal change in each CDH
included wider sensory dermatome and sympathetic dermatome There was a statistically significant
change of temperature in the areas of thermal change in all CDH patients. In conclusion, the areas of
thermal change in CDH can be helpful in diagnosing the level of disc protrusion and in detecting the
symptomatic level in multiple CDH patients.

www.spectronir.com


From the very beginning, Spectron IR set out to build its imaging systems from the ground up using input from experts in the field of medical infrared imaging. Instead of trying to adapt off-the-shelf cameras and industrial software to fit medical uses, Spectron IR started from scratch in order to provide you with the very best. Spectron IR asked technicians and doctors with many years of field experience what they wanted in a new medical infrared imaging system. Spectron IR also teamed up with experts in the field of infrared sensing technology and computerized image processing. What Spectron IR has accomplished is nothing short of providing the finest medical infrared imaging systems available.

www.spectronir.com

Tuesday, September 11, 2012

The use of thermal infrared imaging to assess the efficacy of a therapeutic exercise program in individuals with diabetes.

Abstract

BACKGROUND:

Exercise is of great value for individuals with diabetes in helping to control their hemoglobin A1c levels and in increasing their insulin sensitivity. Delayed-onset muscle soreness (DOMS) is a common problem in healthy individuals and in people who have diabetes. People with diabetes are also faced with metabolic and endothelial impairments, which could make DOMS even worse. But because they usually have neuropathies, they may not feel this soreness appropriately, leading to premature return to exercise and causing further injuries.

RESEARCH DESIGN:

One hundred eighteen subjects participated in this study and were divided into four groups. Two groups (healthy and diabetes) performed a series of abdominal exercises, and the other two groups (healthy and diabetes) performed a series of arm exercises to induce DOMS. Skin temperature above the muscle was assessed using a thermal infrared camera, and perceived soreness of the exercised muscle was assessed using a 100-mm visual analog scale. Serum myoglobin concentrations were also measured.

RESULTS:

There was a significant increase in skin temperature 24 h post-exercise for all four exercise groups (P<0.05), where the combined average increase in skin temperature for all four groups was approximately 0.65°C from baseline. Also, 24 h post-exercise, all four groups were significantly sorer than they were at baseline (P<0.05). Serum myoglobin levels were also significantly higher on day 3 compared with day 1 (P<0.05).

CONCLUSION:

Infrared thermal imaging may be a valuable technique of seeing which muscles are sore hours or even days after the exercise is over. Thus, thermal imaging would be an efficient and painless way of looking at DOMS in both healthy individuals and individuals who have diabetes, even if they are facing neurological problems.

Friday, September 7, 2012


Thermal imaging – a hotspot for the future?: A case report

Ronald J Cook, Shobhan Thakore and Neil M Nichol
Accident and Emergency Department, Ninewells Hospital and Medical School, Dundee DD1 9SY, UK

Case report:
A 6-year-old boy presented to accident and emergency with his mother complaining of a painful right elbow following a fall that day. He fell whilst walking up steps and gave a history of directly striking the elbow on the step. He had not been using the arm since. There was a recent history of a comminuted intra-articular fracture of the proximal ulna of the same elbow, and a cast had been removed just 5 weeks previously.

The patient was seen and examined by an experienced A&E senior house officer. He was difficult to assess and was complaining of pain in the entire arm. There was no swelling or deformity and no apparent bony tenderness to the limb. He was unwilling to actively move the elbow joint, however there was a good range of passive movement throughout the arm and good grip strength was noted. An X-ray of the elbow was performed and no bony injury or effusion of the elbow joint was apparent. The child was treated for a soft tissue injury of the elbow, advised regular analgesia and discharged.

The patient represented two days later complaining of persistent pain to the arm. He was now localising pain to the wrist and there was a corresponding area of tenderness over the distal radius. A thermal image was taken of the limb using a hand held FTI Mv thermal imager interfacing with LIPS Mini PC software. The image identified an obvious “hotspot” corresponding to the area of tenderness over the distal radius, which clearly differed from a thermal image of the normal wrist. Subsequent X-ray of the wrist revealed an undisplaced greenstick fracture of the distal radius. The child was treated with a plaster cast, referred to the orthopaedic fracture clinic and made an uneventful recovery.

Thursday, September 6, 2012


What are the benefits of using Medical Infrared Imaging? 

The procedure is simple, fast, performed in a relaxing manner, and is 100% safe. What separates digital infrared imaging from X-ray, MRI, and other structural imaging methods is its ability to locate infrared markers that may indicate inflammation, circulatory problems, neuropathies, and many other health conditions. The FDA has cleared digital infrared imaging as an adjunctive screening tool to be used with structural imaging methods and other tests to help pinpoint possible problems. 

http://goo.gl/gyZRE

Wednesday, September 5, 2012


What are the most important specifications when purchasing a thermal imaging camera?


With regard to the imaging camera itself: the absolute detector resolution (ex. 640x480), spatial resolution, sensitivity, frame rate, spectral band and the type of bolometer are good starting points. The quality of the digital imaging software is also of extreme importance. The ideal imaging system provides exceptional image quality while providing ease of use. Please click here for more important information.

http://spectronir.com/index.php/faq#5

Thursday, August 30, 2012

Ann Plast Surg. 2011 Apr;66(4):324-5.
Images in plastic surgery: digital thermographic photography ("thermal imaging") for preoperative perforator mapping.
Chubb D, Rozen WM, Whitaker IS, Ashton MW.
 The Taylor Laboratory, Jack Brockhoff Reconstructive Plastic Surgery Research Unit, Department of Anatomy and Cell Biology, The University of Melbourne, Parkville, Victoria 3050, Australia.
 
Preoperative imaging to identify the location of individual perforators has been shown to improve operative outcomes, and while computed tomographic angiography (CTA) and magnetic resonance angiography are currently the most widely used modalities, these have substantial limitations. Such limitations include the need for intravenous access, the need for iodinated contrast media, radiation exposure with CTA, and long scanning times with magnetic resonance angiography. Complications from the use of contrast media are also noteworthy, and can include anaphylactoid reactions and renal toxicity. In a move to avoid these problems, we have recently introduced a technique that is readily available and easy to implement for preoperative imaging, and may show an accuracy that matches the more advanced imaging modalities. Thermal imaging is a readily performed technique, and can be undertaken by the reconstructive surgeon themselves at the initial consultation, enabling prompt operative planning, and avoiding the need for delays in imaging, confusion in the interpretation of a radiologist report, and the need for an intermediary radiologist altogether. In our experience thus far, the technique matches the accuracy for location of CTA, and a larger clinical trial of the technique is underway.
 

http://www.thermology.com/research2010.html

Wednesday, August 29, 2012


Dent Mater J. 2003 Dec;22(4):436-43.

Application of thermography in dentistry--visualization of temperature distribution on oral tissues.

Komoriyama M, Nomoto R, Tanaka R, Hosoya N, Gomi K, Iino F, Yashima A, Takayama Y, Tsuruta M, Tokiwa H, Kawasaki K, Arai T, Hosoi T, Hirashita A, Hirano S.; Department of Dental Engineering, Tsurumi University School of Dental Medicine, 2-1-3 Tsurumi, Tsurumi-ku, Yokohama 230-8501, Japan.

The purpose of this study was to devise and propose appropriate conditions for the photographing of thermal images in the oral cavity and to evaluate which thermography techniques can be applied to dentistry by evaluating the differences in temperature among oral tissues. Thermal images of oral cavities of 20 volunteers in normal oral condition were taken according to the guidelines of the Japanese Society of Thermography, with five added items for oral observation. The use of a mirror made it possible to take thermal images of the posterior portion or palate. Teeth, free gingiva, attached gingiva and alveolar mucosa were identified on thermal images. There were differences in temperature between teeth, free gingiva, attached gingiva and alveolar mucosa. These were nearly in agreement with the anatomical view. Thermography need no longer be restricted to the anterior portion using a mirror, and can now be applied to the dental region.

Tuesday, August 28, 2012

There are many uses for thermography in a small or large practice including adjunctive breast cancer detection, thyroid abnormality detection, visualizing inflammatory conditions and musculoskeletal conditions.

In tough economic times, having a new stream for revenue is vital and invigorating. It adds revenues to the practice and you can claim additional tax incentives for 2012.

Medical thermal imaging emits NO radiation, uses no consumables such as film, and works in synergy with many of today’s common diagnostic procedures.

www.spectronir.com


Thursday, August 23, 2012




Infrared thermography in newborns: the first hour after birth.

Gynakol Geburtshilfliche Rundsch 2003;43(1):31-5

Christidis I, Zotter H, Rosegger H, Engele H, Kurz R, Kerbl R. Department of Pediatrics, University of
Graz, Austria.

"OBJECTIVE: It was the aim of this study to investigate the surface temperature in newborns within the
first hour after delivery. Furthermore, the influence of different environmental conditions with regard to
surface temperature was documented. METHODS: Body surface temperature was recorded under
several environmental conditions by use of infrared thermography. 42 newborns, all delivered at term and
with weight appropriate for date, were investigated under controlled conditions. RESULTS: The surface
temperature immediately after birth shows a uniform picture of the whole body; however, it is significantly
lower than the core temperature. Soon after birth, peripheral sites become cooler whereas a constant
temperature is maintained at the trunk. Bathing in warm water again leads to a more even temperature
profile. Radiant heaters and skin-to-skin contact with the mother are both effective methods to prevent
heat loss in neonates. CONCLUSIONS: Infrared thermography is a simple and reliable tool for the
measurement of skin temperature profiles in neonates. Without the need of direct skin contact, it
may be helpful for optimizing environmental conditions at delivery suites and neonatal intensivecare
units."

Ref. S. Karger AG, Basel

Infrared Thermography in newborns 

Wednesday, August 22, 2012


Re. Breast Thermography

“Infrared imaging, based more on process than structural changes, and requiring neither
contact, compression, radiation nor venous access, provides pertinent and practical
complimentary information to both clinical examination and mammography. Quality
controlled abnormal infrared images heighten our index of suspicion in cases where
clinical or mammographic findings are equivocal or nonspecific and signal the need for
further investigation rather than observation. With the addition of infrared imaging, our
sensitivity of image detection has increased from 83% to 93%.

John Keyserlingk M.D. Ph.D.
Oncological Surgeon
Ville Marie Breast and Oncology Center

Tuesday, August 21, 2012


Medical Thermal Imaging provides real-time access to hidden diagnostic indicators for a variety of conditions. The Spectron IR high resolution imaging system provides a professional adjunctive diagnostic
and evaluation tool for the integrative health care practitioner.

Spectron IR’s software is unique utilizing an “open” interpretation design that allows the user a choice of any qualified interpretation service. The ideal imaging system provides exceptional image quality while providing ease-of-use.

Spectron IR’s software was developed from the ground up with input from some of the worlds leading experts in clinical thermography. Every aspect of the software was designed from both the
technician’s and doctor’s point of view. This is why Spectron IR’s software is so simple to use-yet powerful enough for the rigid demands of board certified clinical thermologists.

www.spectronir.com